Electroretinography

ADAM Health 2 minute read November 4, 2019

Alternative names: ERG; Electrophysiologic testing

Definition: Electroretinography is a test to measure the electrical response of the eye’s light-sensitive cells, called rods and cones. These cells are part of the retina (the back part of the eye).


How the Test is Performed

While you are in a sitting position, the health care provider places numbing drops into your eyes, so you will not have any discomfort during the test. Your eyes are held open with a small device called a speculum. An electrical sensor (electrode) is placed on each eye.

The electrode measures the electrical activity of the retina in response to light. A light flashes, and the electrical response travels from the electrode to a TV-like screen, where it can be viewed and recorded. The normal response pattern has waves called A and B.

The provider will take the readings in normal room light and then again in the dark, after allowing 20 minutes for your eyes to adjust.


How to Prepare for the Test

No special preparation is necessary for this test.


How the Test will Feel

The probes that rest on your eye may feel a little scratchy. The test takes about 1 hour to perform.


Why the Test is Performed

This test is done to detect disorders of the retina. It is also useful for determining if retinal surgery is recommended.


Normal Results

Normal test results will show a normal A and B pattern in response to each flash.


What Abnormal Results Mean

The following conditions may cause abnormal results:


Risks

The cornea may get a temporary scratch on the surface from the electrode. Otherwise, there are no risks with this procedure.


Considerations

You should not rub your eyes for an hour after the test, as this could injure the cornea. Your provider will talk to you about the results of the test and what they mean for you.

References

Baloh RW, Jen JC. Neuro-ophthalmology. In: Goldman L, Schafer AI, eds. Goldman-Cecil Medicine. 25th ed. Philadelphia, PA: Elsevier Saunders; 2016:chap 424.

Miyake Y, Shinoda K. Clinical electrophysiology. In: Schachat AP, Sadda SVR, Hinton DR, Wilkinson CP, Wiedemann P, eds. Ryan’s Retina. 6th ed. Philadelphia, PA: Elsevier; 2018:chap 10.

Reichel E, Klein K. Retinal electrophysiology. In: Yanoff M, Duker JS, eds. Ophthalmology. 5th ed. Philadelphia, PA: Elsevier; 2019:chap 6.9.

DISCLAIMER The information provided herein should not be used during any medical emergency or for the diagnosis or treatment of any medical condition. A licensed physician should be consulted for diagnosis and treatment of any and all medical conditions. Links to other sites are provided for information only -- they do not constitute endorsements of any other sites. Content provided by A.D.A.M and is prepared for the United States of America. Recommended treatments may not be applicable, available, or permissible in Canada or other jurisdictions. A.D.A.M. is accredited by URAC, also known as the American Accreditation HealthCare Commission (www.urac.org). URAC’s accreditation program is an independent audit to verify that A.D.A.M. follows rigorous standards of quality and accountability. A.D.A.M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health on the Net Foundation (www.hon.ch).